Wholesale Leasing Equipment—Cyclonic dewater package with produced water treatment Manufacturer, Supplier

A test skid with one debulky water hydrocyclone unit installed of two DW hydrocyclone liners and two deoiling hydrocyclone units of each installed of a single liner MF type. The three hydrocyclone units are designed in series to be used for testing the practical well stream with high water content at specific field conditions. With that test debulky water and deoiling hydrocyclone skid, it would be able to foresee the real result of water removal and produced water quality, if the hydrocyclone liners to be used for the exact field and operational conditions.

Product Description

Production Capacities & Properties

ParameterMin.NormalMax.
Gross liquid Stream (cu m/hr)1.42.42.4
Inlet Oil content (%)21550
Oil density (kg/m³)800820850
Dynamic viscosity (Pa.s)-Normal-
Water density (kg/m³)-1040-
Fluids temperature (°C)233085

Inlet/Outlet Conditions

ParameterMin.NormalMax.
Operating pressure (kPag)60010001500
Operating temperature (°C)233085
Pressure drop of oil side (kPag)<250
Water outlet pressure (kPag)<150
Produced oil specificationTo remove 50% or above water
Produced water specification< 40 ppm

Technical Specifications

Connection PointSizeRatingType
Well Stream Inlet2”300# ANSI/FIG.1502RFWN
Water Outlet2”150# ANSI/FIG.1502RFWN
Oil Outlet2”150# ANSI/FIG.1502RFWN

System Configuration: Two rotary flowmeters are installed at the water and oil outlets. Six differential pressure gauges are equipped for monitoring the inlet-oil outlet and inlet-water outlet of each hydrocyclone unit.

Dimensions & Weight: 1600mm (L) x 900mm (W) x 1600mm (H) | 700kg

Frequently Asked Questions

What is the maximum fluid temperature handling? The system is designed to handle fluid temperatures up to 85°C.
What is the oil removal efficiency? The system is capable of removing 50% or more of the water content.
How is the flow monitored? Two rotary flowmeters are integrated into the water and oil outlets for precise measurement.
Are pressure gauges included? Yes, the unit comes equipped with six differential pressure gauges for inlet and outlet monitoring.
What is the overall weight of the unit? The unit has a total weight of 700kg.